• 60W ultra-thin stepped-type DIN rail power supply HDR-60-24
  • 60W ultra-thin stepped-type DIN rail power supply HDR-60-24
  • 60W ultra-thin stepped-type DIN rail power supply HDR-60-24
  • 60W ultra-thin stepped-type DIN rail power supply HDR-60-24
  • 60W ultra-thin stepped-type DIN rail power supply HDR-60-24
  • 60W ultra-thin stepped-type DIN rail power supply HDR-60-24
  • 60W ultra-thin stepped-type DIN rail power supply HDR-60-24
  • 60W ultra-thin stepped-type DIN rail power supply HDR-60-24
  • 60W ultra-thin stepped-type DIN rail power supply HDR-60-24
  • 60W ultra-thin stepped-type DIN rail power supply HDR-60-24
  • 60W ultra-thin stepped-type DIN rail power supply HDR-60-24
  • 60W ultra-thin stepped-type DIN rail power supply HDR-60-24

60W ultra-thin stepped-type DIN rail power supply HDR-60-24

No.004
  • 60W ultra-thin stepped-type DIN rail power supply HDR-60-24
  • 60W ultra-thin stepped-type DIN rail power supply HDR-60-24
  • 60W ultra-thin stepped-type DIN rail power supply HDR-60-24
  • 60W ultra-thin stepped-type DIN rail power supply HDR-60-24
  • 60W ultra-thin stepped-type DIN rail power supply HDR-60-24
  • 60W ultra-thin stepped-type DIN rail power supply HDR-60-24

Description

1. Product Certifications

LPS, IS13252, UL, us, UL508, EAC, CB, ID 2000000000, BS EN/EN61558, RoHS, TPTC004, IEC62368-1, AS/NZS60950-1, UL62368-1, CE

2. Product Features

  • Ultra-slim design: 52.5mm (3SU) width
  • Universal input: 85~264VAC (277VAC applicable)
  • No-load power consumption: <0.3W
  • Class II insulation
  • LPS (Limited Power Source) approved
  • Adjustable DC output voltage
  • Protection: Short circuit / Overload / Overvoltage
  • Natural convection cooling; operating temperature: -30~+70°C
  • Mountable on TS-35/7.5 or TS-35/15 DIN rail
  • LED power indicator
  • 3-year warranty

3. Applications

  • Home control systems
  • Building automation
  • Industrial control systems
  • Factory automation
  • Electromechanical equipment

4. Product Description

The HDR-60 is a cost-effective, ultra-slim, IEC-standard 60W DIN rail power supply designed for mounting on TS-35/7.5 or TS-35/15 rails. With a compact 52.5mm (3SU) width, it saves significant cabinet space.
The entire series supports a universal 85VAC~264VAC input (277VAC compatible) and complies with the EU harmonic current standard BS EN/EN61000-3-2.
Housed in a plastic enclosure for electric-shock protection, it achieves up to 91% efficiency and operates reliably from -30°C to +70°C. It features complete protection functions and certifications including IEC62368-1, UL508, UL62368-1, and BS EN/EN61558-2-16, making it a competitive solution for residential and industrial automation.

5. Model Number Definition

HDR-60-XX
  • HDR-60: Series + Rated Power
  • XX: Output voltage (e.g., 12 = 12V, 24 = 24V)

6. Electrical Specifications

表格
Item HDR-60-5 HDR-60-12 HDR-60-15 HDR-60-24 HDR-60-48
Output - DC Voltage 5V 12V 15V 24V 48V
Rated Current 6.5A 4.5A 4A 2.5A 1.25A
Current Range 0~6.5A 0~4.5A 0~4A 0~2.5A 0~1.25A
Rated Power 32.5W 54W 60W 60W 60W
Ripple & Noise (Max.) 80mVp-p 120mVp-p 120mVp-p 150mVp-p 240mVp-p
Voltage Adjustment Range 5.0~5.5V 10.8~13.8V 13.5~18V 21.6~29V 43.2~55.2V
Voltage Accuracy ±2.0% ±1.0% ±1.0% ±1.0% ±1.0%
Line / Load Regulation ±1.0% / ±1.0% ±1.0% / ±1.0% ±1.0% / ±1.0% ±1.0% / ±1.0% ±1.0% / ±1.0%
Start-up / Rise Time 500ms, 50ms/230VAC; 500ms, 50ms/115VAC (full load) Same as left Same as left Same as left Same as left
Hold-up Time 30ms/230VAC; 12ms/115VAC (full load) Same as left Same as left Same as left Same as left
Input - Voltage Range 85~264VAC (277VAC applicable); 120~370VDC (390VDC applicable) Same as left Same as left Same as left Same as left
Input - Frequency Range 47~63Hz Same as left Same as left Same as left Same as left
Efficiency (Typ.) 85% 88% 89% 90% 91%
AC Current (Typ.) 1.2A/115VAC; 0.8A/230VAC Same as left Same as left Same as left Same as left
Inrush Current (Typ.) Cold start: 30A/115VAC; 60A/230VAC Same as left Same as left Same as left Same as left

7. Protection Functions

  1. Overload
    105%~160% of rated output power; hiccup mode when output voltage <50%, constant current mode when 50%~100%; auto-recovery after fault removal.
  2. Overvoltage
    Shut-down output, auto-recovery after restart; threshold: 5.75~6.75V / 14.2~16.2V / 18.8~22.5V / 30~36V / 56.5~64.8V (per model).

8. Environmental Specifications

  • Operating temperature: -30~+70°C (see derating curve)
  • Operating humidity: 20~90% RH, non-condensing
  • Storage temperature / humidity: -40~+85°C, 10~95% RH, non-condensing
  • Temperature coefficient: ±0.03%/°C (0~50°C)
  • Vibration: 10~500Hz, 2G, 10min/cycle, 60min per axis; IEC60068-2-6 compliant
  • Operating altitude: 2000m
  • Overvoltage category: III

9. Safety & EMC

9.1 Safety Standards

EN62368-1, IEC62368-1, BIS IS13252(Part1):2010/IEC 60950-1:2005;
Dielectric strength: I/P-O/P: 4KVAC;
Insulation resistance: 100M Ohms/500VDC/25°C/70% RH

9.2 EMC - Emission

  • Conducted: BS EN/EN55032 (CISPR32), CNS15936 Class B
  • Radiated: BS EN/EN55032 (CISPR32), CNS15936 Class B
  • Harmonic current: BS EN/EN61000-3-2 Class A
  • Voltage flicker: BS EN/EN61000-3-3

9.3 EMC - Immunity

  • ESD: BS EN/EN61000-4-2 Level 3 (8KV air) / Level 2 (4KV contact), criteria A
  • Radiated immunity: BS EN/EN61000-4-3 Level 3, criteria A
  • EFT/Burst: BS EN/EN61000-4-4 Level 3, criteria A
  • Surge: BS EN/EN61000-4-5 Level 4, 2KV/L-N, criteria A
  • Conducted immunity: BS EN/EN61000-4-6 Level 3, criteria A
  • Magnetic field: BS EN/EN61000-4-8 Level 4, criteria A
  • Voltage dips / interruptions: BS EN/EN61000-4-11

10. Other Parameters

  • MTBF: 3524.8K hrs min. (Telcordia SR-332); 927.6K hrs min. (MIL-HDBK-217F, 25°C)
  • Dimensions: 52.5×90×54.5mm (W×H×D), tolerance ±0.5mm
  • Packaging: 190g/pc; 60pcs/13Kg/0.91CUFT
  • Compatible DIN rail: TS35/7.5 or TS35/15

11. Terminal Pin Definition

表格
Pin No. Function Pin No. Function
1, 2 -V 5 AC/L
3, 4 +V 6 AC/N

12. Notes

  1. All specifications are measured at 230VAC input, full load, 25°C ambient unless otherwise noted.
  2. Ripple & noise measurement: 12" twisted pair, 0.1μF + 47μF capacitors at load end, 20MHz bandwidth.
  3. Voltage accuracy includes setting error, line regulation, and load regulation.
  4. This power supply is a system component; EMC verification required with end equipment. See MEAN WELL website for test guidelines.
  5. For altitude >2000m, derate ambient temperature by 3.5°C per 1000m (fanless) or 5°C per 1000m (fan-cooled).
  6. Some models do not carry the BIS mark; contact MEAN WELL sales for details.

CONTACT US

If you have any queries, get in touch today! Don't hesitate. We try to take the extra step for our customer satisfaction.
Name
Email *
Message
Verification Code *
Click to verify
Leave a message
Name
Email *
Message
Verification Code *
Click to verify