Description

1. Basic Specifications & Parameters

Input Parameters

Parameter Value
Control Voltage Range 3–32 VDC
Minimum Control Current 5 mA
Maximum Control Current 15 mA
Guaranteed Turn-On Voltage 3.5 VDC
Guaranteed Turn-Off Voltage 1.5 VDC

Output Parameters
Parameter Value Range
Output Voltage Range 24–480 VAC
Max Load Current 10A / 25A / 40A / 60A / 80A / 100A / 120A
Peak Voltage 800VAC (10/25/40A); 1200VAC (60/80/100/120A)
Insulation Resistance 1000 MΩ / 500VDC
OFF-State Leakage Current ≤8mA rms (10/25/40A); ≤2mA rms (60–120A)
ON-State Voltage Drop ≤1.5V
Turn-On/Off Response Time ≤10 ms

General Characteristics
Parameter Value
Dimensions 57.4L × 44.8W × 28H mm
Weight 100g
Input-Output Insulation Withstand 2500V rms
Input-Output to Housing Withstand 4000V rms
Operating Temperature -20°C ~ +75°C
Mounting Bolt-mounted
Certifications CE

 

2. Model Selection Guide

The model naming format is: XRE - [Design No.] [Phase/Control Type] [Rated Voltage] [Rated Current] [Switching Mode]
  • Rated Output Current: 10A / 25A / 40A / 60A / 80A / 100A / 120A
  • Rated Output Voltage: 22/220V, 48/480V, 38/380V, 66/660V, 120/1200V
  • Phase: 1 (Single-phase), 2 (Two-phase), 3 (Three-phase)
  • Control Type: D (DC control AC), A (AC control AC), DD (DC control DC)
  • Switching Mode: No code = Zero-crossing type; P = Random type
    • Zero-crossing type: Constant current control (3–32VDC, trigger current ≥5mA)
    • Random type: Series resistance control (4–8VDC, trigger current ≥10mA)

3. Key Functional Features

  • Wide input voltage range (3–32VDC) with low control current (≤15mA)
  • No moving mechanical parts: Long service life and high reliability
  • Fast switching speed: Zero-voltage turn-on and zero-current turn-off, reducing RF interference
  • Built-in RC absorption circuit: Protects against inrush current at startup
  • Optical isolation between input and output: 2500V insulation withstand voltage
  • Compact, epoxy-potted design: Vibration-proof, moisture-proof, and corrosion-resistant

Notes

  • Models ≥50A are enhanced solid-state relays and require proper heat sinking.
  • Random-type solid-state relays require a ballast resistor; consult technical support for details.
  • Recommended mounting torque: 0.58–0.98 N·m (M4 screws) and 0.98–1.37 N·m (M3 screws). Excessive torque may damage the relay.
  • Ensure tight contact with the heat sink during installation and apply thermal grease for efficient heat dissipation.